ipmiconsole(8)                  System Commands                 ipmiconsole(8)



NAME
       ipmiconsole - IPMI console utility

SYNOPSIS
       ipmiconsole [OPTION...]

DESCRIPTION
       ipmiconsole  is a Serial-over-LAN (SOL) console utility. It can be used to establish console sessions to remote
       machines using the IPMI 2.0 SOL protocol.

       Ipmiconsole communicates with a remote machine's Baseboard Management Controller (BMC) to establish  a  console
       session.  Before  any  SOL  communication can take place, the remote machine's BMC must be configured properly.
       The FreeIPMI tool bmc-config(8) may be used to do this configuration.

       Often (although not always), console redirection must be also be configured properly in the BIOS and/or operat-
       ing  system. Both must be configured to redirect console traffic out the appropriate COM port.  Please see your
       motherboard and OS documentation for instructions on proper setup.

       Listed below are general IPMI options, tool specific options, trouble shooting information, workaround informa-
       tion, examples, and known issues. For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS
       The  following  options  are general options for configuring IPMI communication and executing general tool com-
       mands.

       -h IPMIHOST, --hostname=IPMIHOST[:PORT]
              Specify the remote host to communicate with. An optional port can be specified, which may be  useful  in
              port forwarding or similar situations.

       -u, --username=USERNAME
              Specify  the  username  to use when authenticating with the remote host.  If not specified, a null (i.e.
              anonymous) username is assumed. The user must a high enough privilege to establish  a  SOL  session  and
              have SOL session abilities.

       -p PASSWORD, --password=PASSWORD
              Specify  the  password to use when authenticationg with the remote host.  If not specified, a null pass-
              word is assumed. Maximum password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt for password to avoid possibility of listing it in process lists.

       -k K_G, --k-g=K_G
              Specify the K_g BMC key to use when authenticating with the remote host for IPMI 2.0. If not  specified,
              a  null key is assumed. To input the key in hexadecimal form, prefix the string with '0x'. E.g., the key
              'abc' can be entered with the either the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt for k-g to avoid possibility of listing it in process lists.

       --session-timeout=MILLISECONDS
              Specify the session timeout in milliseconds. Defaults to 60000 milliseconds (60 seconds) if  not  speci-
              fied.

       --retransmission-timeout=MILLISECONDS
              Specify the packet retransmission timeout in milliseconds. Defaults to 500 milliseconds (0.5 seconds) if
              not specified.

       -I, --cipher-suite-id=CIPHER-SUITE-ID
              Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID identifies  a  set  of  authentication,
              integrity,  and  confidentiality  algorithms to use for IPMI 2.0 communication. The authentication algo-
              rithm identifies the algorithm to use for session setup, the integrity algorithm  identifies  the  algo-
              rithm  to  use for session packet signatures, and the confidentiality algorithm identifies the algorithm
              to use for payload encryption. Defaults to cipher suite ID 3 if not specified. The user should be  aware
              that  only  cipher  suite ids 3, 8, and 12 encrypt console payloads. Console information will be sent in
              the clear if an alternate cipher suite id is selected. The following cipher suite ids are currently sup-
              ported:

              0 - Authentication Algorithm = None; Integrity Algorithm = None; Confidentiality Algorithm = None

              1 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = None; Confidentiality Algorithm = None

              2  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality Algorithm
              = None

              3 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality  Algorithm
              = AES-CBC-128

              6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None; Confidentiality Algorithm = None

              7 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-MD5-128; Confidentiality Algorithm =
              None

              8 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-MD5-128; Confidentiality Algorithm =
              AES-CBC-128

              11  -  Authentication  Algorithm  = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm =
              None

              12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =  MD5-128;  Confidentiality  Algorithm  =
              AES-CBC-128

              15  -  Authentication  Algorithm  = HMAC-SHA256; Integrity Algorithm = None; Confidentiality Algorithm =
              None

              16 - Authentication Algorithm = HMAC-SHA256;  Integrity  Algorithm  =  HMAC_SHA256_128;  Confidentiality
              Algorithm = None

              17  -  Authentication  Algorithm  =  HMAC-SHA256; Integrity Algorithm = HMAC_SHA256_128; Confidentiality
              Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
              Specify the privilege level to be used. The currently available privilege levels are USER, OPERATOR, and
              ADMIN. Defaults to ADMIN if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify workarounds to vendor compliance issues. Multiple workarounds can be specified separated by com-
              mas. A special command line flag of "none", will indicate no workarounds (may be useful  for  overriding
              configured defaults). See WORKAROUNDS below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

IPMICONSOLE OPTIONS
       The following options are specific to Ipmiconsole.

       -e CHAR, --escape-char=CHAR
              Specify an alternate escape character (default char '&').

       -N, --dont-steal
              Do not steal an SOL session if one is already detected as being in use. Under most circumstances, if SOL
              is detected as being in use, ipmiconsole will attempt to steal the SOL session away  from  the  previous
              session.   This  default behavior exists for several reasons, most notably that earlier SOL sessions may
              have not been able to be deactivate properly.

       -T, --deactivate
              Deactivate a SOL session if one is detected as being in use and exit.

       --serial-keepalive
              Occasionally send NUL characters to detect inactive serial connections. This option is particularly use-
              ful  for  those  who  intend  to run ipmiconsole without much interaction, such as for logging purposes.
              While IPMI connections may still be alive, some motherboards have exhibited  bugs  in  which  underlying
              serial  data  can  no  longer be sent/received. From the viewpoint of ipmiconsole, data is simply not be
              sent out of the remote system and this problem is only detected once there is user interaction. By send-
              ing  the  occasional NUL character, the underlying loss of serial data transfer can be detected far more
              quickly. There is some risk with this option, as the NUL character byte may  affect  the  remote  system
              depending on what data it may or may not be expecting.

       --serial-keepalive-empty
              This  option  is  identical  to --serial-keepalive except that SOL packets will contain no NUL character
              data. On some motherboards, this may be sufficient to deal with a hanging IPMI session without the  risk
              regularly  sending a NUL character byte may have. However, some systems may not ACK a SOL packet without
              character data in it, meaning these keepalive packets do nothing.

       -L, --lock-memory
              Lock sensitive information (such as usernames and passwords) in memory.


ESCAPE CHARACTERS
       The following escape sequences are supported. The default supported escape character is '&', but can be changed
       with the -e option.

       &?     Display a list of currently available escape sequences.

       &.     Terminate the connection.

       &B     Send a "serial-break" to the remote console.

       &D     Send a DEL character.

       &&     Send a single escape character.

GENERAL TROUBLESHOOTING
       Most often, IPMI problems are due to configuration problems.

       IPMI  over  LAN problems involve a misconfiguration of the remote machine's BMC.  Double check to make sure the
       following are configured properly in the remote machine's BMC: IP address, MAC address, subnet mask,  username,
       user  enablement,  user privilege, password, LAN privilege, LAN enablement, and allowed authentication type(s).
       For IPMI 2.0 connections, double check to make sure the cipher suite privilege(s) and K_g  key  are  configured
       properly. The bmc-config(8) tool can be used to check and/or change these configuration settings.

       In  addition  to  the  troubleshooting tips below, please see WORKAROUNDS below to also if there are any vendor
       specific bugs that have been discovered and worked around.

       Listed below are many of the common issues for error messages.   For  additional  support,  please  e-mail  the
       <freeipmi-usersATgnu.org> mailing list.

       "username  invalid"  -  The  username  entered (or a NULL username if none was entered) is not available on the
       remote machine. It may also be possible the remote BMC's username configuration is incorrect.

       "password invalid" - The password entered (or a NULL password if none was entered) is not correct. It may  also
       be possible the password for the user is not correctly configured on the remote BMC.

       "password  verification  timeout" - Password verification has timed out.  A "password invalid" error (described
       above) or a generic "session timeout" (described below) occurred.  During this point in the protocol it  cannot
       be differentiated which occurred.

       "k_g invalid" - The K_g key entered (or a NULL K_g key if none was entered) is not correct. It may also be pos-
       sible the K_g key is not correctly configured on the remote BMC.

       "privilege level insufficient" - An IPMI command requires a higher user privilege than  the  one  authenticated
       with.  Please  try to authenticate with a higher privilege. This may require authenticating to a different user
       which has a higher maximum privilege.

       "privilege level cannot be obtained for this user" - The privilege level you  are  attempting  to  authenticate
       with  is higher than the maximum allowed for this user. Please try again with a lower privilege. It may also be
       possible the maximum privilege level allowed for a user is not configured properly on the remote BMC.

       "authentication type unavailable for attempted privilege level" - The authentication type you wish to authenti-
       cate  with is not available for this privilege level. Please try again with an alternate authentication type or
       alternate privilege level. It may also be possible the available authentication types you can authenticate with
       are not correctly configured on the remote BMC.

       "cipher  suite  id  unavailable"  -  The  cipher suite id you wish to authenticate with is not available on the
       remote BMC. Please try again with an alternate cipher suite id. It may also be possible  the  available  cipher
       suite ids are not correctly configured on the remote BMC.

       "ipmi 2.0 unavailable" - IPMI 2.0 was not discovered on the remote machine. Please try to use IPMI 1.5 instead.

       "connection timeout" - Initial IPMI communication failed. A number of potential errors are possible,  including
       an invalid hostname specified, an IPMI IP address cannot be resolved, IPMI is not enabled on the remote server,
       the network connection is bad, etc. Please verify configuration and connectivity.

       "session timeout" - The IPMI session has timed out. Please reconnect.  If this error occurs often, you may wish
       to increase the retransmission timeout. Some remote BMCs are considerably slower than others.

IPMICONSOLE TROUBLESHOOTING
       The following are common issues for error messages in ipmiconsole.

       "SOL  unavailable"  -  SOL is not configured for use on the remote BMC.  It may be not configured in general or
       for the specific user specified. Authenticating with a different user may be sufficient, however the IPMI  pro-
       tocol does not reveal detail on what is not configured on the remote BMC.

       "SOL in use" - SOL is already in use on the remote BMC. If you do not specify the --dont-steal option, ipmicon-
       sole will attempt to steal the SOL session away from the other session.

       "SOL session stolen" - Your SOL session has been stolen by another session. You may wish to try and  steal  the
       session back by reconnecting.

       "SOL  requires  encryption" - SOL requires a cipher suite id that includes encryption. Please try to use cipher
       suite id 3, 8, or 12.  It may also be possible the encryption requirements are not configured correctly on  the
       remote BMC.

       "SOL  requires  no encryption" - SOL requires a cipher suite id that does not use encryption. Please try to use
       cipher suite id 0, 1, 2, 6, 7, or 11. It may also be possible the encryption requirements  are  not  configured
       correctly on the remote BMC.

       "BMC Implementation" - The BMC on the remote machine has a severe problem in its implementation. Please see the
       WORKAROUNDS section below for possible workarounds. If additional vendor workarounds are required, please  con-
       tact the authors.

       "excess retransmissions sent" - An excessive number of retransmissions of SOL packets has occurred and ipmicon-
       sole has given up. This may be due to network issues or SOL issues. Some of the same issues involved with "con-
       nection timeout" or "session timeout" errors may be involved.  Please try to reconnect.

       "excess  errors received" - An excessive number of SOL packet errors has occurred and ipmiconsole has given up.
       This may be due to network issues or SOL issues.  Please try to reconnect.

       "BMC Error" - This error usually means a vendor SOL implementation requires a  combination  of  authentication,
       encryption,  privilege, etc. that have not been met by the user's choices.  Please try a combination of differ-
       ent cipher suites, privileges, etc. to resolve the problem. Please see the WORKAROUNDS section below for possi-
       ble workarounds too.

WORKAROUNDS
       With  so  many  different  vendors implementing their own IPMI solutions, different vendors may implement their
       IPMI protocols incorrectly. The following describes a number  of  workarounds  currently  available  to  handle
       discovered  compliance  issues. When possible, workarounds have been implemented so they will be transparent to
       the user. However, some will require the user to specify a workaround be used via the -W option.

       The hardware listed below may only indicate the hardware that a problem was discovered on.  Newer  versions  of
       hardware  may  fix  the problems indicated below. Similar machines from vendors may or may not exhibit the same
       problems. Different vendors may license their firmware from the same IPMI firmware  developer,  so  it  may  be
       worthwhile to try workarounds listed below even if your motherboard is not listed.

       If  you  believe  your  hardware  has an additional compliance issue that needs a workaround to be implemented,
       please contact the FreeIPMI maintainers on <freeipmi-usersATgnu.org> or <freeipmi-develATgnu.org>.

       authcap - This workaround flag will skip early checks for username capabilities,  authentication  capabilities,
       and  K_g  support and allow IPMI authentication to succeed. It works around multiple issues in which the remote
       system does not properly report username capabilities, authentication capabilities, or K_g status.  Those  hit-
       ting this issue may see "username invalid", "authentication type unavailable for attempted privilege level", or
       "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4,  Intel  SR1520ML/X38ML,  and  Sun  Fire
       2200/4150/4450 with ELOM.

       intel20  -  This workaround flag will work around several Intel IPMI 2.0 authentication issues. The issues cov-
       ered include padding of usernames, and password truncation if the  authentication  algorithm  is  HMAC-MD5-128.
       Those  hitting  this  issue  may  see  "username  invalid",  "password invalid", or "k_g invalid" errors. Issue
       observed on Intel SE7520AF2 with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will work around several Supermicro IPMI 2.0 authentication issues on moth-
       erboards  w/  Peppercon IPMI firmware. The issues covered include handling invalid length authentication codes.
       Those hitting this issue may see "password invalid" errors.  Issue observed  on  Supermicro  H8QME  with  SIMSO
       daughter card. Confirmed fixed on newerver firmware.

       sun20  - This workaround flag will work work around several Sun IPMI 2.0 authentication issues. The issues cov-
       ered include invalid lengthed hash keys, improperly hashed keys, and invalid cipher suite records.  Those  hit-
       ting  this  issue  may see "password invalid" or "bmc error" errors.  Issue observed on Sun Fire 4100/4200/4500
       with ILOM.  This workaround automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI 2.0 connection protocol  to  workaround
       an  invalid hashing algorithm used by the remote system. The privilege level sent during the Open Session stage
       of an IPMI 2.0 connection is used for hashing keys instead of the privilege level sent during the RAKP1 connec-
       tion  stage.  Those hitting this issue may see "password invalid", "k_g invalid", or "bad rmcpplus status code"
       errors.  Issue observed on Sun Fire 4100/4200/4500 with ILOM, Inventec 5441/Dell Xanadu II,  Supermicro  X8DTH,
       Supermicro  X8DTG,  Intel  S5500WBV/Penguin  Relion  700,  Intel S2600JF/Appro 512X, and Quanta QSSC-S4R//Appro
       GB812X-CN. This workaround is automatically triggered with the "sun20" workaround.

       integritycheckvalue - This workaround flag will work around an invalid integrity check value during an IPMI 2.0
       session  establishment  when using Cipher Suite ID 0. The integrity check value should be 0 length, however the
       remote motherboard responds with a non-empty field. Those hitting this issue  may  see  "k_g  invalid"  errors.
       Issue  observed  on  Supermicro  X8DTG,  Supermicro  X8DTU,  and  Intel  S5500WBV/Penguin Relion 700, and Intel
       S2600JF/Appro 512X.

       solpayloadsize - This workaround flag will not check for valid SOL payload sizes and assume a  proper  set.  It
       works  around  remote  systems that report invalid IPMI 2.0 SOL payload sizes. Those hitting this issue may see
       "BMC Implementation" errors. Issue observed on Asus P5M2/RS162-E4/RX4, Intel SR1520ML/X38ML, Inventec 5441/Dell
       Xanadu  II, Sun x4100, Supermicro X8DTH, Supermicro X8DTG, Supermicro X8DTU, and Quanta QSSC-S4R//Appro GB812X-
       CN.

       solport - This workaround flag will ignore alternate SOL ports specified during the protocol. It  works  around
       remote  systems  that report invalid alternate SOL ports. Those hitting this issue may see "connection timeout"
       errors. Issue observed on Asus P5MT-R and Supermicro X8DTH-iF.

       solstatus - This workaround flag will not check the current activation status of SOL during the protocol setup.
       It works around remote systems that do not properly support this command. Those hitting this issue may see "BMC
       Error" errors. Issue observed on Supermicro X8SIL-F.

KNOWN ISSUES
       On older operating systems, if you input your username,  password,  and  other  potentially  security  relevant
       information  on  the  command line, this information may be discovered by other users when using tools like the
       ps(1) command or looking in the /proc file system. It is generally more secure to  input  password  information
       with options like the -P or -K options. Configuring security relevant information in the FreeIPMI configuration
       file would also be an appropriate way to hide this information.

       In order to prevent brute force attacks, some BMCs  will  temporarily  "lock  up"  after  a  number  of  remote
       authentication  errors. You may need to wait awhile in order to this temporary "lock up" to pass before you may
       authenticate again.

       Some motherboards define an OEM SOL inactivity timeout for SOL sessions. If SOL sessions stay inactive for long
       periods  of time, ipmiconsole sessions may be abruptly closed, most likely resulting in session timeout errors.
       Please see OEM notes for information on modifying this parameter if  you  wish  for  sessions  to  stay  active
       longer.

SPECIFIC HARDWARE NOTES
       Intel  SR1520ML/X38ML:  After  a  reboot, the SOL session appears to "disconnect" from the motherboard but stay
       alive.  Character data input from the ipmiconsole client is accepted by the remote machine,  but  no  character
       data  or console data is ever sent back from the remote machine. The SOL session is subsequently useless. There
       is currently no workaround in place to handle this. The session must be closed and restarted.

EXAMPLES
       # ipmiconsole -h ahost -u myusername -p mypassword

       Establish a console sesssion with a remote host.


KNOWN ISSUES
       On older operating systems, if you input your username,  password,  and  other  potentially  security  relevant
       information  on  the  command line, this information may be discovered by other users when using tools like the
       ps(1) command or looking in the /proc file system. It is generally more secure to  input  password  information
       with options like the -P or -K options. Configuring security relevant information in the FreeIPMI configuration
       file would also be an appropriate way to hide this information.

       In order to prevent brute force attacks, some BMCs will temporarily "lock up" after a number of remote  authen-
       tication  errors.  You  may  need  to  wait  awhile in order to this temporary "lock up" to pass before you may
       authenticate again.

REPORTING BUGS
       Report bugs to <freeipmi-usersATgnu.org> or <freeipmi-develATgnu.org>.

COPYRIGHT
       Copyright (C) 2007-2012 Lawrence Livermore National Security, LLC.
       Copyright (C) 2006-2007 The Regents of the University of California.

       This program is free software; you can redistribute it and/or modify it under the terms of the GNU General Pub-
       lic  License as published by the Free Software Foundation; either version 3 of the License, or (at your option)
       any later version.

SEE ALSO
       freeipmi.conf(5), freeipmi(7), bmc-config(8)

       http://www.gnu.org/software/freeipmi/



ipmiconsole 1.2.1                 2017-03-22                    ipmiconsole(8)